© 2009 Directed Electronics
13
Main harness wiring guide
H1/1 ORANGE (-) 500 mA ground-when-armed output: This wire sup-
plies a (-) ground as long as the system is armed. This output ceases as
soon as the system is disarmed. This wire controls operation of the pre-
wired starter kill relay and can be used to control other optional acces-
sories.
NNoottee::
If connecting the orange wire to control another mod-
ule, such as a 529T or 530T window controller, a 1 amp
diode (type 1N4004) will be required. Insert the diode as
shown below.
IImmppoorrttaanntt!!
Never interrupt any wire other than the starter wire.
Komentarze do niniejszej Instrukcji