Directed Electronics Viper ESP 540 Przewodnik Instalacji Strona 172

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 171
TEST REPORT
Page 27 of 33
Issue Date: 2
nd
March 2010.
SGS Serial Number:
AUT130731/4/GH/10.
Test Report
Date: 01-14-2010 Time: 16:19:22
AUT: 130731/1.
Company Name :
Directed Electronics Inc.
Equipment Tested :
Avital 3001L.
Serial Number :
Not marked.
Test Equipment used :
TESEQ Generators
Test Procedure Used :
ISO 7637 - 2.
Test Number 1
Test Name 12vp4.
Test Type Pulse 4
Sequence Repetition Count 1
Test Status PASS. A.
Segment Number # 1 RAMP
Parameter Mode Initial Value Final Value
Amplitude Static 12 Vpp - - -
Parameter Value
Segment Duration 100 ms
Segment Number # 2 RAMP
Parameter Mode Initial Value Final Value
Amplitude Linear 12 Vpp 6 Vpp
Parameter Value
Segment Duration 5 ms
Segment Number # 3 RAMP
Parameter Mode Initial Value Final Value
Amplitude Static 6 Vpp - - -
Parameter Value
Segment Duration 15 ms
Segment Number # 4 RAMP
Parameter Mode Initial Value Final Value
Amplitude Linear 6 Vpp 8 Vpp
Parameter Value
U
K
A
p
p
r
o
v
a
l
A
u
t
h
o
r
i
t
y
25-Mar-10
Przeglądanie stron 171

Komentarze do niniejszej Instrukcji

Brak uwag