56 GOSSEN Mueller & Weigert
Order Example:
Active Power Meter for 3-Wire System, Unbalanced Load,
100/5 A Transformer Ratio, 400 V, Measuring Range: 0 ... 60 kW
Order No.: 3210D AB4 BE11 CG100 IL340 NB: 0 ... 60 kW
Front Dim. in mm 96 x 96
Type LM 96-250
Order no.
3210D
System Type / Power Type Voltage Path Terminal
2-Wire System
Active Power, Single Phase AC AB1 +
at transformer sec.: 100 V primary voltage: ... V BF12 DG ... +
primary voltage: ... kV BF12 DH ... +
at transformer sec.: 110 V primary voltage: ... V BF15 DG ... +
primary voltage: ... kV BF15 DH ... +
direct, 220 VAC IL322 −+
direct, 230 VAC IL323 −+
direct, 240 VAC IL324 −+
Reactive Power, Single Phase AC AB11 +
direct, 220 VAC IL322 −+
direct, 230 VAC IL323 −+
direct, 240 VAC IL324 −+
3-Wire System
Active Power, 3-Wire, Balanced Load AB2 +
Reactive Power, 3-Wire, Balanced Load AB12 +
Active Power, 3-Wire, Unbalanced Load AB4 +
Reactive Power, 3-Wire, Unbalanced Load AB14 +
at transformer sec.: 100 V primary voltage: ... V BF12 DG ... +
primary voltage: ... kV BF12 DH ... +
at transformer sec.: 110 V primary voltage: ... V BF15 DG ... +
primary voltage: ... kV BF15 DH ... +
direct, 380 VAC IL338 −+
direct, 400 VAC IL340 −+
direct, 415 VAC IL661 −+
direct, 440 VAC IL344 −+
direct, 500 VAC IL350 −+
4-Wire System
Active Power, 4-Wire, Balanced Load AB5 +
Reactive Power, 4-Wire, Balanced Load AB15 +
Active Power, 4-Wire, Unbalanced Load AB6 +
Reactive Power, 4-Wire, Unbalanced Load AB16 +
at transformer sec.: 100 V primary voltage: ... V BF12 DG ... +
primary voltage: ... kV BF12 DH ... +
at transformer sec.: 110 V primary voltage: ... V BF15 DG ... +
primary voltage: ... kV BF15 DH ... +
direct, 220/380 VAC IL718 −+
direct, 230/400 VAC IL723 −+
direct, 240/415 VAC IL721 −+
direct, 254/440 VAC IL722 −+
direct, 277/480 VAC IL724 −+
Current Path Terminal at transformer sec.: 1 A primary voltage: ... V BE10 CG ... +
primary voltage: ... kV BE10 CH ... +
at transformer sec.: 5 A primary voltage: ... V BE11 CG ... +
primary voltage: ... kV BE11 CH ... +
Zero Point left −−− +
center BC2 −− +
10% of positive upper value BC6 −− +
Upper Measuring Range Value (adjustable from 0.6 to 1.2 times apparent power) NB ... −− +
Order Number Instructions:
• Select one model each for order numbers with the same sequence of letters.
• No additional entries are required for standard models (identified with bold typeface and “−” in order no. column).
• An entry with “....” in the order no. column means that the order number must be supplemented with written text.
➡
Square Panel Meters
for Active or Reactive Power, 240˚ Scale
Order Information
Code: B0