46 GOSSEN Mueller & Weigert
Moving-Coil Movement, 90° Scale,
White Rail-Mount Housing,
DIN EN 50022 - 35 x 7.5 or
DIN EN 50022 - 35 x 15
Front Dimensions 45 x 45 mm
Type Pqs 45 T
Scale Length 37 mm
Accuracy Class 1.5
Weight in kg, Approx. 0.14
Nominal Insulation Voltage 660 V
Test Voltage 2 kV
Front Housing-Panel Protection IP 50
Housing Material polycarbonate
Interchangeable Scale yes
Type Pqs 45 T
Rail-Mount Indicators
for Direct Current or Direct Voltage
Technical Data
Description
Analog Indicator with Moving-Coil Movement, for Mounting to Top-Hat Rail
or Wall
Reference Conditions
Internal Resistance / Voltage Drop / Power Consumption
1
)
1) Please inquire regarding internal resistance (Ri) for moving-coil indicators with mechanical zero point at any desired
scale value.
Dimensions
Display
Scale Graduation Coarse-fine
Pointer Beam pointer with knife-edge
Mechanical Design
Housing Material Polycarbonate, self-extinguishing and drip-proof per UL94V-0
Replaceable Scale
Terminals M4 screw terminals
M4 screw terminals with self-lifting terminal clips. Screws can
be turned with cross-head or standard screw drivers.
Contact Protection Available as option
Reference Quantities Reference Condition
Ambient Temperature 23°C ± 2°C
Position of Use control panel vertical ± 1°
Other DIN EN 60051
Measuring Range Ri
1 mA 79 Ω ± 20%
1.5 mA 37.5 Ω ± 20%
2 mA 21 Ω ± 20%
2.5 mA 11.4 Ω ± 20%
4 mA 6.7 Ω ± 30%
5 mA 4.8 Ω ± 30%
6 mA 3 Ω ± 30%
10 mA 3.4 Ω ± 30%
15 mA 4 Ω ± 30%
20 mA 3 Ω ± 30%
25 mA 2.4 Ω ± 30%
> 25 mA Voltage drop 60 mV ± 20%
Connection to shunt Power consumption 6 mA ± 20%
≥ 60 mV 1000 Ω/V ± 20%
1) Full contact protection
Front Dim. in mm Nominal Dimensions, mm Cutout, mm Installation Depth, mm Terminals
a
1
x a
2
I
1
x I
2
t e
45 x 45 45 x 45 – 54 2