17
© 2003 directed electronics, inc.
step 9
Optional connections (channel 2, 3)
When the system receives the code controlling channel 2, for
longer than 1.5 seconds, the RED/WHITE wire (H1/12-
channel 2) will supply an output as long as the transmission
continues. This is often used to operate a trunk/hatch release or
other relay-driven function.
When the system recieves the code controlling channel 3, the
output is instantaneous, and the WHITE/BLUE wire (H1/3-
channel 3) will supply an output as long as the transmission
continues. This is used to operate an accessory function.
iimmppoorrttaanntt::
Never use these wires to drive anything but a
relay or a low-current input! The transistorized output
can only supply 200 mA of current. Connecting directly
to a solenoid, motor, or other high-current device will
cause it to fail.