Directed Electronics Python 574 Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Alarm samochodowy Directed Electronics Python 574. Directed Electronics Python 574 User`s manual [en] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 64
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 0
(044)361-05-06
(067)469-02-12
(099)048-99-03
(093)672-77-76
ICQ:495-089-192
ICQ:613-211-859
User's Manual
Car Alarm Python 574 Responder LC3 SST (5704P) Two Way with Remote Engine Start
In the online store Winauto you also can buy car alarm remote engine starter Python 574 Responder LC3 SST
(5704P). Delivery in Kyiv and throughout Ukraine with payment upon receipt!
winauto.ua
Archive - Audio, video - Sound and Components - Security Systems - Video observation and parking - Car Goods - Automotive Lighting - Tweak -
Car Chemicals and Power Supply - Sale -
Przeglądanie stron 0
1 2 3 4 5 6 ... 63 64

Podsumowanie treści

Strona 1 - User's Manual

(044)361-05-06(067)469-02-12(099)048-99-03(093)672-77-76ICQ:495-089-192ICQ:613-211-859User's ManualCar Alarm Python 574 Responder LC3 SST (5704P)

Strona 2

6© 2011 Directed Electronics. All rights reserved.6Responder LC 2-WayCommandButtonsDisplayFunction ButtonMini-USB PortInternalAntennaFeature Descripti

Strona 3 - What you get

7© 2011 Directed Electronics. All rights reserved.At a Glance7Control CenterStatus LEDControl buttonThe Control Center, typically located on the upper

Strona 4 - Important information

8© 2011 Directed Electronics. All rights reserved.Status Screen Icons1ALLText FieldStatus ScreenIconsThe table below describes all the status screen i

Strona 5 - Contents

9© 2011 Directed Electronics. All rights reserved.At a Glance9Icon DescriptionRemote Start+Smart Start is On; Remote Start is On.Note: When the icon i

Strona 6

10© 2011 Directed Electronics. All rights reserved.10Icon DescriptionRemote Control StatusBars indicate battery level is Full, ¾,½,¼ or EmptyOn while

Strona 7

11© 2011 Directed Electronics. All rights reserved.Commands11Using your SystemCommands and ConfirmationsCommands, Basic or Advanced, are used to activa

Strona 8 - Getting Started

12© 2011 Directed Electronics. All rights reserved.12Responder LC Command tableButtonLevelDirect Accessx 1LEVEL 1x 2LEVEL 2x 3LEVEL 3x 4LEVEL 4Arm/Loc

Strona 9 - Keys to using this manual

13© 2011 Directed Electronics. All rights reserved.Commands13** Remote Start feature not available when the Remote Start status is incorrect upon rec

Strona 10 - Responder LC 2-Way

14© 2011 Directed Electronics. All rights reserved.14Basic Commands (Direct Access)ArmPress and release The alarm arms, doors lock (if connected), and

Strona 11 - Control Center

15© 2011 Directed Electronics. All rights reserved.Commands15AUX/TrunkPress and hold AUXThe Trunk opens (if connected) when this button is pressed for

Strona 12 - Status Screen

Online-store car audio and autogoods Winautowinauto.ua

Strona 13 - At a Glance

16© 2011 Directed Electronics. All rights reserved.16Advanced Commands: (Level 1)Press and release the button 1 time.Silent ArmPress and release The

Strona 14

17© 2011 Directed Electronics. All rights reserved.Commands17Runtime ResetPress and release If more time is needed while remote start is active, runti

Strona 15 - Using your System

18© 2011 Directed Electronics. All rights reserved.18Advanced Commands: (Level 2)Press and release the button 2 times.Sensor BypassPress and release

Strona 16 - Fault Condition Alerts

19© 2011 Directed Electronics. All rights reserved.Commands19Timer Start*Press and release Activates (or if On, deactivates) Timer Start. The parking

Strona 17

20© 2011 Directed Electronics. All rights reserved.20Advanced Commands: (Level 3)Press and release the button 3 times.Sensor Silent Arm*Press and rel

Strona 18

21© 2011 Directed Electronics. All rights reserved.Commands21Smart Start**Press and release Activates (or if On, deactivates) Smart Start. The parking

Strona 19 - Remote Start

22© 2011 Directed Electronics. All rights reserved.22Advanced Commands: (Level 4)Press and release the button 4 times.Full Silent Arm*Press and relea

Strona 20 - Advanced Commands: (Level 1)

23© 2011 Directed Electronics. All rights reserved.Configurations23Responder LC ConfigurationOperations of the Responder LC and how it communicates mes

Strona 21 - Temp Request

24© 2011 Directed Electronics. All rights reserved.24Main MenuThe following Main Menu list of features is available for configuration of the remote con

Strona 22 - Advanced Commands: (Level 2)

25© 2011 Directed Electronics. All rights reserved.Configurations25Off after 72 hours if the remote control is not used during this period. Just press

Strona 23 - Runtime Remaining

Congratulations Congratulations on the purchase of your state-of-the-art security and re-mote start system. Reading this Owner’s Guide prior to using

Strona 24 - Advanced Commands: (Level 3)

26© 2011 Directed Electronics. All rights reserved.Runtime AlertOptions: ON,OFFThe main unit will send a page to alert you when the runtime is about t

Strona 25 - Alarm Report*

27© 2011 Directed Electronics. All rights reserved.Configurations27Button BeepOptions: ON,OFFWhen set to ON, the remote will emit a beep as confirmatio

Strona 26 - level 4

28© 2011 Directed Electronics. All rights reserved.28Pair Remote:Remote Pair is a process where the Responder LC and the system in the vehicle learn e

Strona 27 - Responder LC Configuration

29© 2011 Directed Electronics. All rights reserved.Configurations29Demo mode:Demo Mode plays a pre-selected group of animations as a demon-stration to

Strona 28 - Main Menu

30© 2011 Directed Electronics. All rights reserved.30Alarm FeaturesNormal Arm ProtectionStatus LED: The Control Center Status LED flashes as a visual i

Strona 29 - Remote Start Info

31© 2011 Directed Electronics. All rights reserved.Feature Details31Full Silent Arm ProtectionSensor Warn-away, Sensor Full Trigger and Point of Entry

Strona 30 - Temp Unit

32© 2011 Directed Electronics. All rights reserved.32Trigger Zone Fault ReportWhen armed by remote command the system runs a status check of the alarm

Strona 31

33© 2011 Directed Electronics. All rights reserved.Feature Details33Table of ZonesZone # (led flashes) Zone Name1 Tr

Strona 32 - Pair Remote:

34© 2011 Directed Electronics. All rights reserved.34Remote Start FeaturesPit Stop ModeTo exit vehicle with engine runningThe system keeps the engine

Strona 33 - Power Off:

35© 2011 Directed Electronics. All rights reserved.Feature Details35then after a few seconds the remote plays the REMOTE START OFF message.4. The veh

Strona 34 - Alarm Features

Important information Government Regulations and Safety information Read the Government Regulations and Warning! Safety First sections of this manual

Strona 35 - Emergency Override

36© 2011 Directed Electronics. All rights reserved.36Timer Start operation Activation begins a countdown timer as set by the installer (de-fault 3 hou

Strona 36 - Alarm Report when disarming

37© 2011 Directed Electronics. All rights reserved.Feature Details37NoteTemperature report must be turned on by an authorized Di-rected dealer.Remote

Strona 37 - Nuisance Prevention (NPC)

38© 2011 Directed Electronics. All rights reserved.6. Exit the vehicle, close all the doors and arm the system.7. The engine turns off and after a f

Strona 38 - Remote Start Features

39© 2011 Directed Electronics. All rights reserved.Feature Details39Remote Start ErrorFor user safety, the system must be properly configured or remote

Strona 39 - Advanced Start

40© 2011 Directed Electronics. All rights reserved.40Remote and System OperationsPassive Arming*Park and exit the vehicle, after the doors are closed

Strona 40 - Temperature Reporting

41© 2011 Directed Electronics. All rights reserved.Feature Details41Valet ModeValet mode can be entered and exited by performing the Remote Valet comm

Strona 41 - Remote Start Time-out Alert

42© 2011 Directed Electronics. All rights reserved.42Out of RangeEach time a command is performed the remote will expect a com-mand confirmation from t

Strona 42 - Turbo Timer Mode

43© 2011 Directed Electronics. All rights reserved.1-Way431-way Companion Remote ControlLEDCommandButtonsFunctionButtonButtonLevelDirect Accessx 1LEVE

Strona 43 - Remote Start Error

44© 2011 Directed Electronics. All rights reserved.44Using the 1 way companion remoteThe companion 1 way remote commands the system features as shown

Strona 44 - Remote and System Operations

45© 2011 Directed Electronics. All rights reserved.1-Way45ProgrammingTo enter; hold the button for 8 seconds, the remote emits one long beep and turn

Strona 45 - Automatic Remote Updates

ContentsGetting Started ... 4Charging the remote cont

Strona 46 - Feature not Available

46© 2011 Directed Electronics. All rights reserved.46Battery Information (1-Way)The 1way companion remote is powered by one 3V coin cell lithium batte

Strona 47 - Function

47© 2011 Directed Electronics. All rights reserved.System Expansion OptionsControlling two vehicles (Car Select)The Responder LC and 1way companion re

Strona 48 - Car Select

48© 2011 Directed Electronics. All rights reserved.Driver door priority unlockingThe door unlocking operation can be configured to emulate an OEM style

Strona 49 - Programming

49© 2011 Directed Electronics. All rights reserved.Battery49Battery Information (Responder LC)The Responder LC remote control is powered by an interna

Strona 50 - Battery Information (1-Way)

50© 2011 Directed Electronics. All rights reserved.50be charged at the earliest opportunity or failure to control the system may occur. Low Battery Al

Strona 51 - System Expansion Options

51© 2011 Directed Electronics. All rights reserved.Battery51Battery DisposalDirected Electronics cares about the environment. If you need to dispose o

Strona 52

52© 2011 Directed Electronics. All rights reserved.Glossary of TermsDocument TerminologyControl Module The “brain” of your system. Usually hidden unde

Strona 53 - Low Battery

53© 2011 Directed Electronics. All rights reserved.Patent InformationThis product is covered by one or more of the following United States patents:Rem

Strona 54 - Battery Life

54© 2011 Directed Electronics. All rights reserved.Government RegulationsThis device complies with Part 15 of FCC rules. Operation is subject to the f

Strona 55 - Battery Disposal

55© 2011 Directed Electronics. All rights reserved.Safety55Control CenterTo satisfy FCC RF exposure compliance requirements, the device and its an-ten

Strona 56 - Glossary of Terms

Main Menu ... 24Setup Remote menu: ...

Strona 57 - Patent Information

56© 2011 Directed Electronics. All rights reserved.56Warning! Safety FirstPlease read the safety warnings below before proceeding. Improper use of the

Strona 58 - Government Regulations

57© 2011 Directed Electronics. All rights reserved.Safety57Before remote starting a manual transmission vehicle, be sure to:s Leave the vehicle in ne

Strona 59

58© 2011 Directed Electronics. All rights reserved.GEAR IS CONTRARY TO ITS INTENDED MODE OF OPERATION. OPER-ATING THE REMOTE START SYSTEM UNDER THESE

Strona 60 - Warning! Safety First

59© 2011 Directed Electronics. All rights reserved.Limited lifetime consumer warrantyDirected Electronics. (“Directed”) promises to the original purch

Strona 61

60© 2011 Directed Electronics. All rights reserved.ANY CONSEQUENTIAL DAMAGES OF ANY KIND. IN THE EVENT OF A CLAIM OR A DISPUTE INVOLVING DIRECTED OR I

Strona 62 - Water/Heat Resistance

Remote and System Operations ... 40Passive Arming ...

Strona 63

4© 2011 Directed Electronics. All rights reserved.Getting StartedYour Responder LC remote is powered by an internal rechargeable battery that can only

Strona 64

5© 2011 Directed Electronics. All rights reserved.At a Glance5Keys to using this manualSpecific actions (in bold type) and style conventions are used c

Komentarze do niniejszej Instrukcji

Brak uwag