c. Additional Equipment. The additional equipment
required to perform the quarterly test procedure is
Oscilloscope AN/USM-281(*).
d. Oscilloscope 7ime Differential (Delay) Measure-
ment Procedure. To provide the greatest accuracy
when measuring delays, certain steps of the quarterly
test procedures (table 4-1) delays shall be measured as
follows:
(1) With oscilloscope sweep display switch set to
MAIN, adjust DIV DELAY control to position inten-
sified trace (reduce INTENSITY setting as necessary
to view) over first point of interest on waveform.
(2) Set sweep display switch to DELAYED.
(3) Readjust DIV DELAY control to position point
of interest on waveform exactly on a vertical reference
line (normally center vertical line of graticule).
(4) Record setting of DIV DELAY control.
(5) Set sweep display switch to MAIN.
(6) Adjust DIV DELAY control to position inten-
sified trace over second point of interest on waveform.
TM 11-6625-2611-12
(7) Set sweep display switch to DELAYED.
(8) Readjust DIV DELAY control to position sec-
ond point of interest on waveform exactly on vertical
reference line (same reference line used in (3) above).
(9) Record setting of DIV DELAY control.
(10) Calculate difference between setting
recorded in (4) above and setting recorded in (9) above.
(11) Multiply MAIN TIME/DIV switch setting by
difference obtained in (10) above to obtain delay be-
tween two points of interest on waveform.
4-10. General Troubleshooting Information
The troubleshooting chart (para 4-11) lists symptoms
that may be observed while performing the operator’s
preventive maintenance checks. If a malfunction oc-
curs, perform the corrective actions indicated. Any
malfunction that is beyond the scope of the operator to
correct shall be referred to a higher category of mainte-
nance.
Table 4-1. Quarterly Test Procedure
1
2
3
4
5
6
7
8
9
10
11
Control Settings
I
Oscilloscope
Set up oscilloscope as
described in para-
graph 2-11c
DISPLAY switch B
B VOLTS/DIV 1.
MAIN TIME/DIV DIV
2 µ sec.
DELAYED TIME/DIV
switch 0.1
µ
sec
Sweep display switch
DELAYED
DELAYED TIME/DIV
switch 0.2
µ
sec
DELAYED TIME/DIV
Test set
[
Test procedure
Power Supply Test
Set up test set as de-
scribed in paragraph
2-11d
Check POWER indicator
Check POWER DC FAULT indica-
tor.
Press POWER DC FAULT indicator.
PRF Generator PRF Measuring Section Test
PRF SELECT RANGE
switch X100 -
MEASUREMENT PRF
RANGE switch X1OO
PRF SELECT RANGE
switch X10
MEASUREMENT PRF
RANGE switch X1O
PRF SELECT switch to
X
1/2
MEASUREMENT PRF
RANGE switch X1K
PRF SELECT RANGE
switch X1K
PRF SELECT switch X1
Adjust PRF SELECT MULT control
until meter indicates 9.0 on Hz
scale.
Adjust PRF SELECT MULT control
until meter indicates 10.0 on Hz
scale.
Adjust PRF SELECT MULT control
until meter indicates 10.0 on Hz
scale.
observe MEASUREMENT meter.
Timing
Marker Test
Observe three sets of markers. Each
set will be of different amplitude
and spacing.
Using time differential measure-
ment procedure described in para
4-9d. Measure spacing between
leading edge of the first lower
amplitude set of pulses.
Observe second set of pulses.
(Amplitude level more than pre-
vious pulses but less than the third
set of pulses.)
Observe third set of pulses with first
Performance standard
POWER indicator illuminates.
POWER DC FAULT indicator is ex-
tinguished.
POWER
DC
FAULT indicator illumi-
nates.
PRF SELECT RANGE and MULT con-
trols indicate prf is 8, 100 to 9,900
Hz.
PRF SELECT RANGE and MULT con-
trols indicate prf is 900 to 1100 Hz.
PRF SELECT RANGE and MULT con-
trols indicate prf is 81 to 110 Hz.
Meter indicates 4.5 to 5.5 on Hz scaIe.
Three sets of markers are present.
Pulses are spaced 0.1 µ sec ±0.02%,
>0.5 volts amplitude.
pulses are spaced 1.0
µ
sec ±0.02%,
>o.5 volt amplitude.
Pulses am spaced 10.0 µ sec ±0.02% ,
4-5