This input comes from the factory set to 2 activation pulses. This means that it is necessary to have 2 consecu-
tive ground pulses on the white/blue wire for the remote start to activate or to deactivate. The same holds true
for the remote control activation when set to a two pulse setting it is necessary to press the button twice
for the remote start to activate or deactivate.
NNOOTTEE::
When the activation pulse count can be programmed to 1, 2, or 3 pulses when changed it
will affect both activation inputs; the White/Blue wire and the remote control activation.
Connect this wire to the optional domelight supervision relay as shown below:
IIMMPPOORRTTAANNTT!!
This output is only intended to drive a relay. It cannot be connected directly to the
domelight circuit, as the output cannot support the current draw of one or more light bulbs.
HH11//44 BBLLAACCKK//WWHHIITTEE ((--)) 220000 mmAA ddoommeelliigghhtt ssuuppeerrvviissiioonn oouuttppuutt
HH11//33 WWHHIITTEE//BBLLUUEE rreemmoottee ssttaarrtt ((--)) aaccttiivvaattiioonn iinnppuutt