DE3
CIRCUIT BREAKERS
01/15
DE3-37
Mission Critical Circuit Breakers
Selective Coordination
Designed for selectively coordinated systems, mission critical circuit breakers maximize continuity of the electrical
service by allowing the branch circuit breaker to clear the fault.
Mission critical circuit breakers are engineered with technology that optimizes current, time and energy selectivity
so the fault is cleared by the circuit breaker immediately upstream of the occurrence. This technology (see figure
below) allows the remaining areas of the electrical system to continue operation without disruption. In addition to
unique design attributes, Square D mission critical circuit breakers have also undergone rigorous testing
procedures to certify the coordination with downstream circuit breakers—combining innovative engineering with
validated test results.
Apply Square D mission critical circuit breakers in emergency power distribution systems, data centers, hospitals
or anywhere continuity of service is desired.
The PowerPact™ J- and L-Frame Mission Critical circuit breakers deliver high levels of selective coordination in a flexible design that can be easily
configured for a variety of applications. Tested to be selectively coordinated with the QO™ family of miniature circuit breakers and the ED, EG, and EJ
circuit breakers, this solution provides peace of mind when power availability is critical.
An electronic trip unit provides adjustable long-time settings in four sensor sizes, allowing coverage from 70 A through 600 A on a 120–240, 208Y/120,
240, 480Y/277, and 480 V systems.
a Standard rated (80%). Not available in 100% rated.
b AL250JD terminal wire range is (1) 3/0 AWG–350 kcmil Al or Cu.
a 250A and 400A MCCB are 100% rated. 600A MCCB are standard (80%) rated.
b AL400L61K3 terminal wire ranges are (1) #2 AWG–500 kcmil Al or (1) #2 AWG–600 kcmil Cu.
c AL600LS52K3 terminal wire ranges are (2) 2/0 AWG–500 kcmil Al or Cu.
PowerPact J- and L-Frame Mission Critical Circuit Breakers
Ratings Available Configurations
UL 489 Listed
CSA Certified
Voltage: 480 V
I-Line mounting
Main circuit breaker in NQ and NF panelboards
Unit mount for OEM users
Plug-in base for OEM users
Drawout base ofr OEM users
J-Frame 250 A Electronic Trip Mission Critical Circuit Breakers (480/277 Vac)
with Factory Sealed Trip Units Suitable for Reverse Connectiona
Electronic Trip
Unit Type
Trip Function Trip Unit
Continuous
Current
D Interrupting G Interrupting J Interrupting L Interrupting
Terminal
Cat. No. Cat. No. Cat. No. Cat. No.
Standard LI 3.2 W 250 JDL34250WU31X JGL34250WU31X JJL34250WU31X JLL34250WU31X AL250JDb
Standard LSI 3.2S-W 250 JDL34250WU33X JGL34250WU33X JJL34250WU33X JLL34250WU33X AL250JDb
High Perf. Ammerter LSI 5.2A-W 250 JDL34250WU43X JGL34250WU43X JJL34250WU43X JJLL34250WU43X AL250JDb
High Perf. Energy LSI 5.2E-W 250 JDL34250WU53X JGL34250WU53X JJL34250WU53X JLL34250WU53X AL250JDb
High Perf. Ammerter LSIG 6.2A-W 250 JDL34250WU44X JGL34250WU44X JJL34250WU44X JLL34250WU44X AL250JDb
High Perf. Energy LSIG 6.2E-W 250 JDL34250WU54X JGL34250WU54X JJL34250WU54X JLL34250WU54X AL250JDb
L-Frame 600 A Electronic Trip Mission Critical Circuit Breakers (480/277 Vac)
with Factory Sealed Trip Units Suitable for Reverse Connectiona
Electronic Trip
Unit Type
Trip Function Trip Unit
Continuous
Current
D Interrupting G Interrupting J Interrupting L Interrupting
Terminal
Cat. No. Cat. No. Cat. No. Cat. No.
480/277 Vac, 50/60 Hz, 3P
Standard LI 3.3 W
250 LDL34250WU31X LGL34250WU31X LJL34250WU31X LLL34250WU31X AL400L61K3b
400 LDL34400WU31X LGL34400WU31X LJL34400WU31X LLL34400WU31X
AL600LS52K3c
600 LDL34600WU31X LGL34600WU31X LJL34600WU31X LLL34300WU31X
Standard LSI 3.3S-W
250 LDL34250WU33X LGL34250WU33X LJL34250WU33X LLL34250WU33X AL400L61K3b
400 LDL34400WU33X LGL34400WU33X LJL34400WU33X LLL34400WU33X
AL600LS52K3c
600 LDL34600WU33X LGL34600WU33X LJL34600WU33X LLL34300WU33X
High Perf. Ammeter LSI 5.3A-W
400 LDL34400WU43X LGL34400WU43X LJL34400WU43X LLL34400WU43X
AL600LS52K3c
600 LDL34600WU43X LGL34600WU43X LJL34600WU43X LLL34300WU43X
High Perf. Energy LSI 5.3E-W
400 LDL34400WU53X LGL34400WU53X LJL34400WU53X LLL34400WU53X
AL600LS52K3c
600 LDL34600WU53X LGL34600WU53X LJL34600WU53X LLL34300WU53X
High Perf. Ammeter LSIG 6.3A-W
400 LDL34400WU44X LGL34400WU44X LJL34400WU44X LLL34400WU44X
AL600LS52K3c
600 LDL34600WU44X LGL34600WU44X LJL34600WU44X LLL34300WU44X
High Perf. Energy LSIG 6.3E-W
400 LDL34400WU54X LGL34400WU54X LJL34400WU54X LLL34400WU54X
AL600LS52K3c
600 LDL34600WU54X LGL34600WU54X LJL34600WU54X LLL34300WU54X
480/277 Vac, 50/60 Hz, 4P
Standard LI 3.3 W
250 LDL44250WU31X LGL44250WU31X LJL44250WU31X LLL44250WU31X AL400L61K4b
400 LDL44400WU31X LGL44400WU31X LJL44400WU31X LLL44400WU31X
AL600LS52K4c
600 LDL44600WU31X LGL44600WU31X LJL44600WU31X LLL44300WU31X
Standard LSI 3.3S-W
250 LDL44250WU33X LGL44250WU33X LJL44250WU33X LLL44250WU33X AL400L61K4b
400 LDL44400WU33X LGL44400WU33X LJL44400WU33X LLL44400WU33X
AL600LS52K4c
600 LDL44600WU33X LGL44600WU33X LJL44600WU33X LLL44300WU33X
High Perf. Ammeter LSI 5.3A-W
400 LDL44400WU43X LGL44400WU43X LJL44400WU43X LLL44400WU43X
AL600LS52K4c
600 LDL44600WU43X LGL44600WU43X LJL44600WU43X LLL44300WU43X
High Perf. Energy LSI 5.3E-W
400 LDL44400WU53X LGL44400WU53X LJL44400WU53X LLL44400WU53X
AL600LS52K4c
600 LDL44600WU53X LGL44600WU53X LJL44600WU53X LLL44300WU53X
High Perf. Ammeter LSIG 6.3A-W
400 LDL44400WU44X LGL44400WU44X LJL44400WU44X LLL44400WU44X
AL600LS52K4c
600 LDL44600WU44X LGL44600WU44X LJL44600WU44X LLL44300WU44X
High Perf. Energy LSIG 6.3E-W
400 LDL44400WU54X LGL44400WU54X LJL44400WU54X LLL44400WU54X
AL600LS52K4c
600 LDL44600WU54X LGL44600WU54X LJL44600WU54X LLL44300WU54X
J-Frame Termination Options
Termination Letter
A = I-Line (See Section 9)
F = No Lugs (includes terminal nut kit on both ends)a
L = Lugs both ends
M = Lugs ON end Terminal Nut Kit OFF end
P = Lugs OFF end Terminal Nut Kit ON end
N = Plug-in b
D=Drawoutb
S = Rear Connected b
a Add TS suffix for circuit breaker without terminal nut kit.
b For N and D termination please refer to page DE3-45. For S termination please refer to page DE3-41.
H- and J-Frame Interrupting Ratings
Voltage
Interrupting Rating
Accessories ........................................PageDE3-39
Optional Lugs .......................................PageDE3-42
Dimensions .........................................PageDE3-55
Enclosures .........................................PageDE3-56
D G J L
240 Vac 25 kA 65 kA 100 kA 125 kA
480 Vac 18 kA 35 kA 65 kA 100 kA
Plug-in
Drawout
Rear Connected
HGL36100
For factory-installed
termination, place termination
letter in the third block of the
circuit breaker catalog number.
Termination Letter
FAULT
QO 20 A 1P
PowerPact D-Frame Mission Critical Circuit Breaker
QO 100 A 2P
208 Y/120 V 3 Phase Panel
Load
Load
06163051
DE3_p037.fm Page 37 Saturday, January 10, 2015 2:31 AM