Directed Electronics K10 Dokumentacja Strona 2

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 16
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 1
2
ATTENTION: K10 GAUGES BOTH STRAIN AND QUARTZ OF ALL SIZES:
DURING ASSEMBLE/ DISASSEMBLE, WRENCHES ARE TO BE PLACED ON
THE CLOSEST FLATS. NO PIPE WRENCHES ARE TO BE USED ON
KUSTER MEMORY GAUGES. WISES WITH ROUND HALF CLAMPS ARE
RECOMMENDED FOR FIXING THE GAUGES FOR DISASSEMBLE
PROCEDURES.
IN ORDER TO AVOID TOOL MALFUNCTIONING, O’RINGS UNDER THE
ELECTRONICS HOUSING SHOULD BE REPLACED STRICTLY ACCORDING
THE PROCEDURE, DESCRIBED AT THE END OF THIS MANUAL.
WARNING: ALL ELECTRONIC GAUGES: UNDER NO CIRCUMSTANCES IS THE
TEMPERATURE RATING OF THE BATTERIES TO BE EXCEEDED.
WORK PREPARATION:
1. Make sure that the tool is able to meet the anticipated requirements of the well to be
surveyed, i.e. pressure and temperature limitations.
2. Make sure that the battery temp limit meets the requirements of the well to be surveyed.
3. Check the battery voltage using the supplied battery tester. With the load adapter
attached to the DMM and the battery turn the selector switch to 20 Vdc. Turn on DMM
and read voltage. The load adapter has 380Ω resistor inside which emulates the board.
The voltage of the battery under 380Ω load should be min 3.1 v for the AA type batter
and min 6.1 v for C type. If the new battery has shown very low voltage, the problem
could be in the battery being passivated. In order to depassivate the battery apply Lo
and Hi loads of the tester.
There is another way of checking the battery. Connect battery to the gauge. First you
will get 1 long flash on battery LED. After that, six or less short flashes. Amount of the
short flashes will indicate approximate voltage of battery. For example, if you will get 6
short flashes, it will indicate, that the battery voltage is about 3.6v, which is a maximum
battery charge level. If it will flash 5 times, then the battery voltage is about 3.5v and so
on. Flickering flash with assigned rate will indicate that gauge start sampling. At 1-
second sample rate you will not get a flickering flash, but a regular short one.
Third method of checking the battery is with a help of the software and is explained in the
software manual.
4. Power comm. box either with gauge battery or thru a wallwart. Connect gauge through
interface-box to the computer.
5. You will get 1 long flash and then 4 short flashes on comm. box for strain gauge and 5
flashes for quartz. After that it will continue to flash in communication mode. If you don’t
get right amount of flashes, tool and battery feasibility should be questioned.
6. Program the gauge with desired rate. (See software manual for a more detailed
explanation of programming options).
CAUTION: DO NOT DISCONNECT GAUGE DURING DATA TRANSMISSION.
7. Disconnect gauge from the interface box.
8. Apply a bead of Kuster hi-temp thread lube to all threads and across o’ring glands.
9. Disconnect the buffer tube assembly from transducer sub.