feature menus
Factory default settings are indicated in bold in the following feature tables.
FEATURE DEFAULT - LED ON SETTING LED OFF SETTING
NUMBER (PRESS CHANNEL 1) (PRESS CHANNEL 2)
1-1 Active arming Passive arming
1-2 Chirps ON Chirps OFF
1-3 Ignition lock ON Ignition lock OFF
1-4 Ignition unlock ON Ignition unlock OFF
1-5 Active locking Passive locking
1-6 Panic with ignition ON Panic with ignition OFF
1-7 Door lock pulse duration 0.8 seconds Door lock pulse duration 3.5 seconds.
1-8 Double Unlock Pulse OFF Double Unlock Pulse ON
1-9 Channel 2 delayed validity Channel 2 latched (2), latch reset with ignition
(3), 30 second timed (4)
1-10 FAD with Channel 2 ON FAD with Channel 2 OFF
1-11 Security features ON Security features OFF (starter kill)
1-12 Code Hopping ON Code Hopping OFF
1-13 Channel 4 Validity Latched, Latch reset with ignition, 30-sec.
timed
*NOTE: The numbers in parentheses indicate the number of times the LED will flash.