24 © 2000 Directed Electronics, Inc. Vista, CA
shock sensor harness, 4-pin connector
Inputs shorter than 0.8 seconds will trigger the Warn Away® response, while inputs longer than 0.8 seconds will
trigger full alarm sequence and report Zone Two. If installing an optional DEI® dual stage sensor, connect to the
green wire as shown below. The diagram below eliminates the need for diodes to isolate the sensors.
Diagram for adding optional DEI® dual stage sensor to green wire (Zone 2):
Inputs shorter than 0.8 seconds will trigger the Warn Away® response, while inputs longer than 0.8 seconds will
trigger full alarm sequence and will also report Zone Two.
Do not use these for anything besides the plug-in shock sensor.
RED and BLACK: RED is (+)12V constant, BLACK is (-) ground
BLUE (-) multiplex input, zone 2
GREEN (-) multiplex input, zone 2